Technical Specifications
-
Electrical Models Sentra XL 1000 Sentra XL 1500 Sentra XL 2200 Sentra XL 3000 Input Acceptable Voltage Range 83-159Vac or 160-300Vac Voltage Window 110/120/127Vac or 220/230/240Vac +/-25% Frequency 45~65Hz (auto-sensing) Phase Single phase + ground Output Voltage Range Battery Mode 110/120/127Vac or 220/230/240Vac +/-5% Frequency 50/60Hz Auto-sensing Capacity 1000VA/900W 1500VA/1350W 2100VA/1920W 3000VA/2700W Wave Form Pure Sine Wave Transfer Time 4-6ms typical Efficiency Line Mode: Up to 95%; Boost/Buck Mode: Up to 94% Cold Start Yes Battery Type Sealed Lead Acid Maintenance-free Capacity 12V/7AH 12V/9AH 12V/7AH 12V/9AH Quantity 4 4 8 8 Voltage 24V 24V 48V 48V Autonomy (80% load) 8.6mins 7.1mins 7.9mins 7.3mins Recharge Time 5 hours to 90% after complete discharge at 100% load Display Status on LCD Line bypass, AVR Boost(Buck), Backup, Battery Level, Battery Low, Load Level, Battery Fault, UPS Fault Status on LED Line Mode, Battery Mode, and Fault Self-Diagnostics Upon Power On and Software Control Protection Overload: Line Mode >100%-110% buzzer alarms only >110%-120% for 10 min. and then shutdown >120% shutdown after 1 cycle Overload: Battery Mode >100%-120% buzzer alarms only >120%-130% shutdown after 10 sec. >130% shutdown after 1 cycle Short Circuit: Line Mode Resettable Breaker Short Circuit: Battery Mode Electronic Circuit Low Battery: Alarm and Switch Off EPO: UPS Shuts Down Immediately Battery: Electronic System of Management of Battery Discharge Heat Dissipation 96W 108W 192W 216W Alarms Acoustics and Display Mains Fault, Low Battery, Overload and Fault Conditions Computer Interface Interface Type Standard RS232 and USB Communication Slots Dry Contact Card or SNMP card Compatible Platforms Windows 95/98/NT/2000/XP/Vista/Win7, Novell Netware, Linux, Mac Mechanical Dimensions 88H x 440W x 491D (mm) 88H x 440W x x 701D (mm) 3.5H x 17.3W x 19.3D (inch) 3.5H x 17.3W x 27.6D (inch) Input Connectors: 120Vac NEMA5-15P NEMA 5-20P NEMA L5-30P Input Connectors: 230Vac IEC-320-C14 IEC-320-C20 Output Connectors: 120Vac (8) NEMA 5-15R (6) NEMA 5-15R
(2) NEMA 5-20R(5) NEMA 5-15R
(2) NEMA 5-20R
(1) NEMA L5-30ROutput Connectors: 230Vac (8) IEC-320-C13 (8) IEC-320-C13, (1) IEC-320-C19 Net Weight (120Vac) 25kgs (51lbs) 27.8kgs (61lbs) 41.8kgs (92lbs) 47.8kgs (105lbs) Net Weight (230Vac) 25kgs (51lbs) 27.8kgs (61lbs) 42kgs (93lbs) 46.2kgs (102lbs) Environmental Operating Temperature 0 to 40°C (30 to 104°F) Warning Temperature The battery design life is based on a temperature of 25°C (77°F) Ambient temperature above this range will affect battery life Altitude 0-2000M up to 40°C (104°F); 0~3000M up to 35°C (95°F) Humidity 90% RH Maximum, No Condensing Noise Line Mode: 40 dB Max; Bat. Mode: 45 dB Max. Agency Compliance Quality ISO 9001 certified manufacturing Security EN62040-1-1, UL1778 Performance EN62040-3 Standard EMC EN62040-2, EN61000-3-2, FCC Class A Marking CE, UL, cUL, FCC