Telecommunications
Wireless
UPS
Industrial Power
Service and Support
Cable/Broadband
Renewable Energy
Alpha Catalog
Alpha Webstore
The Alpha Group
The Alpha Group represents an alliance of independent companies who share a common philosophy - to create world class powering solutions.

Collectively, Alpha Group members develop and manufacture AC and DC power conversion protection, and standby products. Applications for these products include broadband, telecom, AC/UPS, commercial, industrial, and distributed generation,
for a worldwide customer base. In addition, our companies provide a range of installation and maintenance services.

Members of The Alpha Group include Alpha Technologies Inc., Alpha Energy, Alpha Industrial Power, Alpha Technologies Ltd. and Altair Advanced Industries Inc.
CSM02
Modular DC to DC Converter
Part number: 012-502-20
  • 48VDC to 24VDC, 10A output
  • 4RU vertical mount — 5 modules in 19in, 6 modules in 23in
  • Scalable hot plug-in operation
  • Convection cooled

The CSM02 is a compact, modular DC-DC converter system designed for communications applications. The CSM02 DC-DC converter utilizes Alpha’ advanced switched-mode technology to provide outstanding efficiency in a compact design. The CSM02 achieves power conversion efficiencies greater than 85 percent at full load, resulting in significant energy savings over competitive units.

The CSM02 incorporates a comprehensive range of standard and optional features allowing it to fulfill an extensive list of applications. Standard features include input/output termination’s, current limit, over voltage protection, test points, over temperature protection and fuses. Options include low temperature operation, low/high voltage alarm, adjustable OVP, fuse distribution, input breaker, on board microprocessor for remote monitoring, and a serial communications interface.

Electrical
Input voltage:40 to 60VDC
Output voltage:22 to 26VDC
Output current:10A
Efficiency:>85% (100% load)
Regulation:-1%, +/-0.1% load (static)
+/-0.1% line (static)
<2% deviation for 50 to 100% load step (dynamic)
Response time:2ms to 0.1% of output for 50 to 100% load step
Noise: 
Voice band:<22dBrnC
Wide band:<10mV RMS (10kHz to 10MHz)
<150mV pk to pk (10kHz to 100MHz)
Acoustic:45 dBa at 1m (3ft)
Mechanical
MechanicalConnections: 
Input/output:Two ¼in studs on ⅝in centers
Alarm/control:Terminal block
0.5mm2 to 1.5mm2 (#20 to 16AWG)
50A (5-module vertical 19in)
Part number: 030-534-20
Dimensions:mm: 178H x 432W x 305D
inches: 7H x 17W x 12D
Weight:16.6kg (36lb) e/w 5 power modules
60A (6-module vertical 23in)
Part number: 030-520-20
Dimensions:mm: 178H x 508W x 305D
inches: 7H x 20W x 12D
Weight:19.5kg (43lb) e/w 6 power modules
Input Module 50 and 60A versions
Part number: 012-513-20
Indicators:Circuit breaker trip
Alarms:Circuit breaker trip alarm
Distribution Fuse Module 20, 50 and 60A versions
Part number: 012-509-20
Indicators:Output fuse fail
Alarms:Output fuse alarm
Fuse block:8 position 0 to 10A GMT fuses (25 & 30A versions)
4 position 0 to 10A GMT fuses (10A version)
Connections:Terminal block
0.75 mm2 to 4 mm2 (#18 to #12 AWG)
Analog Supervisory Module 50 and 60A versions
Part number: 012-508-20
Indicators:Major alarm
System over voltage protection trip
System high voltage alarm
System low voltage alarm
Test mode
Digital voltmeter/ammeter
Alarms:Major alarm
Low voltage alarm
High voltage alarm
Adjustments:Over voltage protection
High voltage alarm
Low voltage alarm
Test/normal selector
Environmental
Temperature:0 to 50C (32 to 122F) with specified ventilation
-40 to 50C (-40 to 122F) (optional)
Humidity:0 to 95% RH non-condensing
Elevation:-500 to 2800m (-1640 to 9186ft)
Indicators:Power on
Output over voltage protection trip
Bar graph output current
Converter fail
Current limit
Alarms:Converter fail alarm
Adjustments:Output voltage
Protection:Input fuse
Input inrush current limiting
Over temperature limiting
Input high and low voltage shutdown
Output paralleling diode
Current limit/short circuit protection
Request Quote